!! New Batch of Solar Power Plant Design & Electrical system Design will going starts from 6th April 2019
Chat with us !
syllabus-advance-electrical-design-institutue

Chapter 1: Basic of rooftop solar power plant

  1. Brief description of Scheme
  2. Net Metering Scheme
  3. Grid Interactive scheme
  4. Grid Connected Scheme
  5. Off-grid Solar Power Plant design
  6. Battery sizing Calculation

Chapter 2 - Solar Radiation

  1. Irradiation and PeakSun Hours
  2. Solar Radiation Data
  3. Sunpath Diagram
  4. Defining the Position of the Sun
  5. Solar Altitude
  6. Geometric Effects
  7. Tilting Solar Modules
  8. Magnetic North & True North

Chapter - 3 Connection of PV Module(Series and Parallel Circuit)

  1. SeriesCircuits
  2. Parallel Circuits
  3. Combining Series & Parallel Circuits
  4. Understanding Cell Connection
  5. Array

Chapter- 4 PV Cells Selection and Sizing

  1. Introduction
  2. Characteristics of a Solar Cell
  3. Power Characteristics of a Solar Cell
  4. Fill factor and Equivalent Solar cell Circuit
  5. STC and NOCT
  6. Factors Which Affect the Performance of Solar Cells
  7. Types of Solar Cells

Chapter- 5 Selection sizing of AC side equipment

  1. AC Distribution board selection
  2. Meter selection (Uni- Directional and Bi-directional)
  3. Feeder selection
  4. String inverter selection

Chapter 6 - Inverters Selection and Sizing(Grid Connection and Off Grid)

  1. Purpose of inverters
  2. Bettery Bank sizing calculation
  3. Grid-Connected Inverters vs. Stand-Alone Inverters
  4. Types of Grid-Connected inverters: Introduction
  5. Isolated Inverters
  6. Types of Inverters - PV to Inverter Interface
  7. Inverter Protection Systems
  8. Power Quality
  9. Monitoring
  10. Inverter Products For Use In India

Chapter 7 - Module Mounting Systems

  1. Introduction
  2. Calculating the Wind Loading of the Solar Array
  3. Roof Mounted Systems
  4. Systems
  5. PV Array Row Spacing
  6. Ground Mounted Systems

Chapter 8- Matching Array and Inverter Sizing

  1. Matching The PV Array ToThe Voltage Specifications of An Inverter
  2. Matching the PVArray to the Inverter's Current Rating
  3. Matching the PVArray to the Inverter's Power Rating
  4. Summary of Calculations for Matching Array and Inverter

Chapter 9 - System Losses of Solar Power Plant

  1. Determining the Size of the DC and AC Cables
  2. Losses in a Grid-Connected PV System

Chapter 10 - Solar power plant Assessment Software

  1. Drafting sofateware
  2. Google Sketchup (shadow Anaylysis software )
  3. PVsyst, meteonorm,
  4. Ref. Std. IEC IEC 60068-2 (1,2,14,30),IEC
    61683,IEC 60227,IEC 60502 IEC 60947 part I,II, III ,IEC 61215